Kullaniş
SABIX® R 605 FRNC is a SABIX® Rail Data cable which is flame retardant and self-extinguishing and fulfils fire protection requirements R 15 (EL1A) acc. to 45545-2 for hazard levels HL1-3. It is recommended for the internal wiring of rail vehicles acc. to EN 45545-2.
Özel özellikler
- halogen-free
- no flame propagation
- flame retardant and self-extinguishing
- fulfils fire protection requirements R15 (EL1A) acc. to EN 45545-2 for hazard levels HL1-3
- flame retardant acc. to UN/ECE R118
Ek bilgi
Especially for use in rail vehicles
Yapı
Conductor | bare copper strands with reference to IEC 60228, EN 6028, VDE 0295, class 5 |
---|---|
Insulation | Special SABIX® |
Colour code | with reference to DIN 47100 |
Stranding | in layers |
Sheath material | Special SABIX® |
Sheath colour | grey (RAL 7032) |
bare copper strands with reference to
IEC 60228, EN 6028, VDE 0295, class 5
Special SABIX®
with reference to DIN 47100
in layers
Special SABIX®
grey (RAL 7032)
Teknik veriler
Peak operating voltage | < 0,25 mm² = max. 350 V ≥ 0,25 mm² = max. 500 V |
---|---|
Testing voltage | < 0,25 mm² = 800 V ≥ 0,25 mm² = 1200 V |
Min. bending radius | fixed laying: 5 x d flexible use: 10 x d |
Temperature range | fixed laying: -40/+90 °C flexible use: -30/+90 °C |
Halogen-free | acc. to EN 50306-1 + EN 50264-1 are fulfilled. Development of HCl is < 0,5% acc. to EN 50267-2-1. pH-value is > 4,3 acc. to EN 50267-2-2. Conductivity is < 10,0 μS/mm acc. to EN 50267-2-2. Fluoric content < 0,1% acc. to EN 60684-2. |
Fire performance | No flame propagation acc. to DIN EN 60332-3-24, DIN EN 60332-3-25 and DIN EN 50305 section 9.1.2. Flame retardant and self-extinguishing acc. to DIN EN 60332-1-2. Flame retardant acc. to ISO 6722 (UN/ECE R118) |
Toxicity | acc. to DIN EN 50305 |
Smoke density | acc. to DIN EN 61034 |
Flexibility | good |
Absence of harmful substances | acc. to RoHS directive of the European Union |
< 0,25 mm² = max. 350 V
≥ 0,25 mm² = max. 500 V
< 0,25 mm² = 800 V
≥ 0,25 mm² = 1200 V
fixed laying: 5 x d
flexible use: 10 x d
fixed laying: -40/+90 °C
flexible use: -30/+90 °C
acc. to EN 50306-1 + EN 50264-1 are fulfilled.
Development of HCl is < 0,5% acc. to EN 50267-2-1.
pH-value is > 4,3 acc. to EN 50267-2-2.
Conductivity is < 10,0 μS/mm acc. to EN 50267-2-2.
Fluoric content < 0,1% acc. to EN 60684-2.
No flame propagation acc. to DIN EN 60332-3-24, DIN EN 60332-3-25 and DIN EN 50305 section 9.1.2.
Flame retardant and self-extinguishing acc. to DIN EN 60332-1-2.
Flame retardant acc. to ISO 6722 (UN/ECE R118)
acc. to DIN EN 50305
acc. to DIN EN 61034
good
acc. to RoHS directive of the European Union